Aquifer Pumping Tests: Design, Field Procedures, Data Analysis and Sustainable Yield Assessment

Learn aquifer pumping test design, field procedures, drawdown and recovery analysis, aquifer parameters and sustainable groundwater yield assessment.

  • ONLINE and Birchwood Hotel, 44 Viewpoint Rd, Bartlett, Boksburg
  • 29 -30 October 2026
  • b
    2 CPD Points
  • Price : From R 8 999.00
Aquifer Pumping Tests

LEARNING OUTCOMES

After successfully completing this course, you will be able to:

Z

Understand groundwater occurrence, flow and storage across different aquifer environments, including South Africa's principal fractured-rock systems.

Z

Build an appropriate conceptual model of an aquifer before designing a test, and use it to select the right test type, monitoring network and analytical approach.

Z

Recognise the field and instrumentation choices that determine data quality, and the common causes of unreliable field data.

Z

Process and quality-check a pumping-test dataset, and build and read the standard diagnostic plots, including drawdown derivatives.

Z

Apply the Flow Characteristics (FC) method used widely in South African fractured-rock practice, and explain its assumptions and known limitations.

Z

Work through realistic and imperfect datasets end-to-end, and translate the results into a defensible technical recommendation and report

Groundwater and Aquifer Fundamentals

  • Groundwater occurrence and movement
  • Recharge and discharge
  • Hydraulic gradients
  • Groundwater-flow systems
  • Groundwater–surface-water interaction
  • Groundwater storage and abstraction
  • Aquifer classification: unconfined, confined, semi-confined/leaky, perched, porous-media, fractured-rock, karst
  • South African groundwater environments: Karoo, Basement/crystalline rock, dolomite/karst, Table Mountain Group
  • Key hydraulic parameters: hydraulic conductivity, transmissivity, storativity, specific storage, specific yield, specific capacity

Conceptualising the Aquifer Before Testing

  • Building a conceptual model: geological setting, aquifer geometry, lithology, water-bearing zones
  • Recharge/discharge mechanisms and expected flow directions
  • Hydraulic boundaries, faults and fractures
  • Surface-water connections and nearby abstraction
  • Using existing information: geological/hydrogeological maps, borehole logs, drilling records, water strikes, static water levels, prior pumping tests
  • Why the conceptual model matters: selecting the test, placing monitoring points, choosing a defensible analytical method, interpreting unexpected behaviour
  • Core principle: the analytical method must fit the aquifer, not the other way around

Principles and Objectives of Aquifer Pumping Tests

  • Why conduct a pumping test: productivity assessment, aquifer characterisation, parameter estimation, operating-condition determination, boundary identification, interference assessment
  • Borehole performance testing vs. aquifer parameter estimation — the key distinction
  • Principal test types: step-drawdown, constant-discharge, recovery
  • Brief overview: multi-well/interference testing, slug testing

Pumping-Test Design and Planning

  • Defining investigation objectives
  • Reviewing hydrogeological information, borehole construction, drilling and water-strike records
  • Establishing expected yield and selecting the test sequence
  • Selecting pumping rates, test duration, monitoring requirements
  • Factors influencing design: aquifer type, pump capacity, available drawdown, intended water use, nearby boreholes, existing abstraction, potential boundaries, discharge-water disposal
  • Monitoring network: pumping borehole, observation boreholes, piezometers, reference points, background monitoring

Equipment, Instrumentation and Field Data Quality

  • Test-pump selection, sizing, installation depth, discharge pipework, flow control
  • Water-level measurement: manual meters, electronic meters, pressure transducers, data loggers
  • Measurement frequency, time synchronisation, reference-datum control
  • Discharge measurement: flow meters, volumetric checks, weirs
  • Field-data quality issues: instrument calibration and drift, timing errors, pump-rate fluctuation, power interruptions, missing observations, interference from other abstraction, rainfall/recharge effects

Step-Drawdown and Constant-Discharge Testing

  • Step-drawdown testing
    • Purpose: assessing borehole productivity through increasing pumping rates
    • Estimating specific capacity, well losses, well efficiency
    • Selecting the rate for the constant-discharge test
  • Constant-discharge testing
    • Purpose and selecting the pumping rate
    • Linking test duration to investigation objective and intended water use
    • Monitoring for delayed responses and boundary effects as the test matures
  • Common field problems: variable discharge, excessive drawdown, dewatering of water-bearing zones, instrument/power failure
  • Detailed SANS 10299-4:2003 numeric reference (step counts, minimum durations, discharge tolerances) provided as a handout table rather than taught live

Recovery Testing

  • Principles: residual drawdown, recovery monitoring, recovery duration, recovery curves
  • Recovery as an independent check on aquifer response
  • Comparing pumping-phase and recovery-phase results
  • Recognising incomplete recovery as a sign of boundary or storage effects
  • Note on accompanying water-quality sampling (EC, temperature, chemical analysis) as standard practice, outside this course's analytical scope

Pumping-Test Data Processing and Quality Control

  • Assembling the dataset: static/pumping water levels, drawdown, discharge, elapsed time, recovery, observation-well response
  • Data-quality assessment: missing data, outliers, timing errors, pump-rate variation, instrument drift, background influences (barometric effects, nearby abstraction, recharge)
  • Building diagnostic plots: drawdown vs. time, semi-log plots, log-log plots, recovery plots

Classical Aquifer-Test Analysis: Theis and Cooper-Jacob

  • Theis type-curve method and its assumptions (confined, homogeneous, isotropic, fully penetrating, infinite aquifer)
  • Cooper-Jacob straight-line approximation, valid time range
  • Estimating transmissivity and storativity
  • Cross-checking Theis vs. Cooper-Jacob, and pumping-phase vs. recovery-phase estimates
  • Key principle: a mathematically correct calculation can still mislead if the aquifer doesn't satisfy the method's assumptions

Diagnostic Interpretation and Flow Regimes

  • Drawdown derivatives and log-log diagnostic plots
  • Early-, intermediate- and late-time behaviour
  • Recognising: wellbore storage, skin effects, radial vs. linear flow, fracture-controlled flow, leakage, recharge/no-flow boundaries, heterogeneity, anisotropy
  • Power and risk of late-time behaviour: strong for boundary identification, risky if over-extrapolated
  • Skills taught here are reused (not retaught) throughout Modules 11–14

Aquifer-Specific Interpretation

  • Confined aquifers: radial flow, late-time response
  • Unconfined aquifers: delayed drainage, specific yield, why confined-aquifer solutions can mislead
  • Leaky aquifers: aquitards, leakage signatures
  • Fractured-rock aquifers: fracture-controlled/dual-porosity flow, discrete water-strike zones, heterogeneity, non-radial behaviour

Flow Characteristics (FC) Method and Its Limitations

  • Background: purpose of the FC approach, South African development and application
  • Applying FC: drawdown derivatives, identifying flow regimes, long-term yield extrapolation
  • Critical evaluation: assumed no-flow boundary conditions, boundary-distance uncertainty, aquifer storativity, extrapolation uncertainty
  • 2024 Water SA review findings on FC's limitations
  • FC as one line of evidence, not a stand-alone sustainable-yield calculator

Borehole Yield, Available Drawdown and Sustainable Abstraction

  • Distinguishing tested yield, maximum instantaneous yield, recommended operating rate, safe/reliable yield, sustainable abstraction
  • Available drawdown: static water level, pump setting, main water strike, minimum operating level
  • What determines sustainable abstraction: recharge, boundaries, storage, interference, seasonal variability, drought, monitoring
  • Why a pumping test alone doesn't determine long-term sustainability