Aquifer Pumping Tests: Design, Field Procedures, Data Analysis and Sustainable Yield Assessment
Learn aquifer pumping test design, field procedures, drawdown and recovery analysis, aquifer parameters and sustainable groundwater yield assessment.
- ONLINE and Birchwood Hotel, 44 Viewpoint Rd, Bartlett, Boksburg
- 29 -30 October 2026
- 2 CPD Points
- Price : From R 8 999.00

LEARNING OUTCOMES
After successfully completing this course, you will be able to:
Understand groundwater occurrence, flow and storage across different aquifer environments, including South Africa's principal fractured-rock systems.
Build an appropriate conceptual model of an aquifer before designing a test, and use it to select the right test type, monitoring network and analytical approach.
Recognise the field and instrumentation choices that determine data quality, and the common causes of unreliable field data.
Process and quality-check a pumping-test dataset, and build and read the standard diagnostic plots, including drawdown derivatives.
Apply the Flow Characteristics (FC) method used widely in South African fractured-rock practice, and explain its assumptions and known limitations.
Work through realistic and imperfect datasets end-to-end, and translate the results into a defensible technical recommendation and report
Groundwater and Aquifer Fundamentals
- Groundwater occurrence and movement
- Recharge and discharge
- Hydraulic gradients
- Groundwater-flow systems
- Groundwater–surface-water interaction
- Groundwater storage and abstraction
- Aquifer classification: unconfined, confined, semi-confined/leaky, perched, porous-media, fractured-rock, karst
- South African groundwater environments: Karoo, Basement/crystalline rock, dolomite/karst, Table Mountain Group
- Key hydraulic parameters: hydraulic conductivity, transmissivity, storativity, specific storage, specific yield, specific capacity
Conceptualising the Aquifer Before Testing
- Building a conceptual model: geological setting, aquifer geometry, lithology, water-bearing zones
- Recharge/discharge mechanisms and expected flow directions
- Hydraulic boundaries, faults and fractures
- Surface-water connections and nearby abstraction
- Using existing information: geological/hydrogeological maps, borehole logs, drilling records, water strikes, static water levels, prior pumping tests
- Why the conceptual model matters: selecting the test, placing monitoring points, choosing a defensible analytical method, interpreting unexpected behaviour
- Core principle: the analytical method must fit the aquifer, not the other way around
Principles and Objectives of Aquifer Pumping Tests
- Why conduct a pumping test: productivity assessment, aquifer characterisation, parameter estimation, operating-condition determination, boundary identification, interference assessment
- Borehole performance testing vs. aquifer parameter estimation — the key distinction
- Principal test types: step-drawdown, constant-discharge, recovery
- Brief overview: multi-well/interference testing, slug testing
Pumping-Test Design and Planning
- Defining investigation objectives
- Reviewing hydrogeological information, borehole construction, drilling and water-strike records
- Establishing expected yield and selecting the test sequence
- Selecting pumping rates, test duration, monitoring requirements
- Factors influencing design: aquifer type, pump capacity, available drawdown, intended water use, nearby boreholes, existing abstraction, potential boundaries, discharge-water disposal
- Monitoring network: pumping borehole, observation boreholes, piezometers, reference points, background monitoring
Equipment, Instrumentation and Field Data Quality
- Test-pump selection, sizing, installation depth, discharge pipework, flow control
- Water-level measurement: manual meters, electronic meters, pressure transducers, data loggers
- Measurement frequency, time synchronisation, reference-datum control
- Discharge measurement: flow meters, volumetric checks, weirs
- Field-data quality issues: instrument calibration and drift, timing errors, pump-rate fluctuation, power interruptions, missing observations, interference from other abstraction, rainfall/recharge effects
Step-Drawdown and Constant-Discharge Testing
- Step-drawdown testing
- Purpose: assessing borehole productivity through increasing pumping rates
- Estimating specific capacity, well losses, well efficiency
- Selecting the rate for the constant-discharge test
- Constant-discharge testing
- Purpose and selecting the pumping rate
- Linking test duration to investigation objective and intended water use
- Monitoring for delayed responses and boundary effects as the test matures
- Common field problems: variable discharge, excessive drawdown, dewatering of water-bearing zones, instrument/power failure
- Detailed SANS 10299-4:2003 numeric reference (step counts, minimum durations, discharge tolerances) provided as a handout table rather than taught live
Recovery Testing
- Principles: residual drawdown, recovery monitoring, recovery duration, recovery curves
- Recovery as an independent check on aquifer response
- Comparing pumping-phase and recovery-phase results
- Recognising incomplete recovery as a sign of boundary or storage effects
- Note on accompanying water-quality sampling (EC, temperature, chemical analysis) as standard practice, outside this course's analytical scope
Pumping-Test Data Processing and Quality Control
- Assembling the dataset: static/pumping water levels, drawdown, discharge, elapsed time, recovery, observation-well response
- Data-quality assessment: missing data, outliers, timing errors, pump-rate variation, instrument drift, background influences (barometric effects, nearby abstraction, recharge)
- Building diagnostic plots: drawdown vs. time, semi-log plots, log-log plots, recovery plots
Classical Aquifer-Test Analysis: Theis and Cooper-Jacob
- Theis type-curve method and its assumptions (confined, homogeneous, isotropic, fully penetrating, infinite aquifer)
- Cooper-Jacob straight-line approximation, valid time range
- Estimating transmissivity and storativity
- Cross-checking Theis vs. Cooper-Jacob, and pumping-phase vs. recovery-phase estimates
- Key principle: a mathematically correct calculation can still mislead if the aquifer doesn't satisfy the method's assumptions
Diagnostic Interpretation and Flow Regimes
- Drawdown derivatives and log-log diagnostic plots
- Early-, intermediate- and late-time behaviour
- Recognising: wellbore storage, skin effects, radial vs. linear flow, fracture-controlled flow, leakage, recharge/no-flow boundaries, heterogeneity, anisotropy
- Power and risk of late-time behaviour: strong for boundary identification, risky if over-extrapolated
- Skills taught here are reused (not retaught) throughout Modules 11–14
Aquifer-Specific Interpretation
- Confined aquifers: radial flow, late-time response
- Unconfined aquifers: delayed drainage, specific yield, why confined-aquifer solutions can mislead
- Leaky aquifers: aquitards, leakage signatures
- Fractured-rock aquifers: fracture-controlled/dual-porosity flow, discrete water-strike zones, heterogeneity, non-radial behaviour
Flow Characteristics (FC) Method and Its Limitations
- Background: purpose of the FC approach, South African development and application
- Applying FC: drawdown derivatives, identifying flow regimes, long-term yield extrapolation
- Critical evaluation: assumed no-flow boundary conditions, boundary-distance uncertainty, aquifer storativity, extrapolation uncertainty
- 2024 Water SA review findings on FC's limitations
- FC as one line of evidence, not a stand-alone sustainable-yield calculator
Borehole Yield, Available Drawdown and Sustainable Abstraction
- Distinguishing tested yield, maximum instantaneous yield, recommended operating rate, safe/reliable yield, sustainable abstraction
- Available drawdown: static water level, pump setting, main water strike, minimum operating level
- What determines sustainable abstraction: recharge, boundaries, storage, interference, seasonal variability, drought, monitoring
- Why a pumping test alone doesn't determine long-term sustainability